MX 57EX (Now Discontinued)
Description
This ATEX-certified 50,000-count TRMS digital multimeter is designed for use in hazardous or explosive “gas” or “dust” environments, incompliance with the following standards:
Mine: Category Ex I M2
Surface industry: Category 2 (gas and dust) EX II 2 gd
Zone 1&2(gas) Ex ib I and Ex ib II T5 or T4 or T3
Zones 21&22(dust) EX ib D21 IP6X T°…°C
The temperature class depends on the battery used.
Certified battery |
Explosive gaseous atmosphere |
Combustible dusty atmosphere |
DURACELL PROCELL |
T5 |
T91 (°C) |
POWER LINE |
T4 |
T103 (°C) |
ANSMANN |
T4 |
T112 (°C) |
SANYO |
T4 |
T123 (°C) |
ENERGIZER |
T4 |
T124 (°C) |
POWER ONE |
T3 |
T133 (°C) |
It meets the following specifications:
– ATEX 2014/34/UE directive
– EN/IEC 60079-0 – EN/IEC 60079-11
– EN/IEC 61241-11 – EN/IEC 61241-0
– EN/IEC 61010-1 – 600 V CAT III+EN61010-2-030 2010
It is certified LCIE 02 ATEX 6005 X and EEx ib IIC T5/ EEx ib I (“old regulations”) as per:
– CE inspection certificate number LCIE 02 ATEX 6005 X and additional clauses LCIE 02 ATEX 6005X / 01, 02, 03, 04
It is equipped with a 500 mA fuse. It is delivered in a bag with some of its accessories.
• Bargraph; zoom or central zero
• VDC from 0.5 to 600 V ,
• AC and AC+DC voltage from 0.5 to 600 V, accuracy 0.025%
• Bandwidth: DC to 50 kHz
• AC and AC+DC current from 500 µA to 500 mA
• Resistance from 500 Ω to 50 MΩ
• MIN, MAX, Average and Peak
• Frequency, capacitance, temperature, dB, resistive power, duty cycle, pulse width/timer, event counter
• Continuity and iode tests