EKX-4 Ground Monitoring Device

 

EKX-4 Ground Monitoring Device

The Timm Grounding Control Devices ensure static electricity that could build up on a Road Tanker during filling or unloading is discharged safely to earth, thus avoiding a potential spark risk.

The system will only give the Green Light and release the interlock to pumps etc when the grounding clamp is correctly fitted to the road tanker and will not operate if it is attached to other metal objects such as a tool or the gantry. If the Earth / Ground connection is interrupted, the filling or unloading process will stop immediately.

The Timm device enclosure is purpose-designed for the system and a heavy Exd or Explosionproof box is not required, thus simplifying installation and on-going maintenance.

 

Available Options

EKX-4 Ground Monitoring Device with 10m spiral cable
EKX-4 Ground Monitoring Device with 10m cable reel
(Both the above with the option of quick release clamp)

 

    Type of Protection: According to ATEX-standard 2014/34/EU:
    Ex II 2 G – Ex eb q [ib] IIC T4 Gb
    Ex II 2 D – Ex tb [ib] IIIC T80°C Db
    EC Type Examination: TÜV 11 ATEX 080882
    Power Supply: 230 V AC ± 10 %, 50 Hz, ca. 10 VA
    type of protection “increased safety“ Ex eb
    Measuring Circuit: Max. Uo = 6, 7 V; Io = 68 mA; Po = 114 mW
    Max. 50 m (ex related specification, functional limitations must be observed)
    Type of protection Ex ib / ibD
    Only for connection of the grounding cable
    The measuring circuit is grounded
    Contact Release Output: Switching power max 250 VAC 3 A 100 VA
    Type of protection “increased safety“ Ex eb
    2 voltage free closing contact, internal monitored
    Auxiliary Output: Switching power max. 250 VAC 3 A 100 VA
    Type of protection “increased safety“ Ex eb
    voltage free changeover contact, not monitored
    Electronic Release Output: Max. Ui = 20 V Ii = 20 mA Pi = 400 mW
    Inner capacitances Ci negligibly small
    Inner inductances Li negligibly small
    Type of protection “intrinsic safety“ Ex ib
    1 NAMUR-compatible transistor output
    Internal resistance: 1 kΩ or 11 kΩ
    Modulation: 10 Hz, duty factor 1:1
    Protection of Enclosure: IP65
    Operation Temperature: – 30 °C up to + 60°C
    Dimensions (W x L x H): 170 mm x 306 mm x 110 mm
    Weight: approx. 4.5 kg